CE ISO Certificate ICU Ventilator Machine S/T, CPAP, S, T, PC, VAT Multifunctional Ventilator
Features
Higher treatment pressure, more leak compensation.
In case of high inhalation pressure support (40cm H20) orlarge air leakage
Inhalation time function:
the minimum spontaneousinhalation time (Timin) prevents premature reversing toexhalation to ensure ventilation time
AST-Premium automatic synchronizationtechnology , excellent man-machine synchronization.
The VAT can provide tidal volume similar to volume contramode, and also has the safety of pressure control mode.
Accurate oxygen concentration control, more efficient to improve Pa02.
The oxvgen concentration isaccurate and constant, the effect of improving bloodoxygen saturation is better.
Inhalation time function.
the minimum spontaneousinhalation time (Timin) prevents premature reversing toexhalation to ensure ventilation time
Complete parameters setting.
8 hours back-up battery.
Application
* Chronic Obstructive Pulmonary Disease
* Acute Cardiac Edema
* Other ventilation problems
* Acute Exacerbation of Chronic Obstructive Pulmonary Disease
* Moderate Acute Respiratory Distress Syndrome
Specifications
Parameter | ST-30H | ST-30K |
Ventilation mode | S/T, CPAP, S, T, PC, VAT | S/T, CPAP, S, T,PC, VAT, HFNC |
Oxygen concentration | 21%-100%, (increment by 1%) | |
Screen size | 5.7 inch color screen | |
Waveform display | Pressure/flow | |
IPAP | 4-30cm H2O | 4-40cm H2O |
EPAR | 4-25cm H2O | |
CPAP | 4-20cm H2O | |
Target tidal volume | 20-2500mL | |
Backup BPM | 1-60BPM | |
Backup time | 0.2 -4.0 S | |
Rise time | 1-6 level | |
Ramp time | 0-60min (increment by 1 min) | |
Ramp pressure | CPAP mode: 4-20cm H20 Other mode: 4-25cm H20 | |
Pressure relief | 1-3 level | |
Spontaneous Timin | 0.2-4.0 S | |
Spontaneous Timax | 0.2-4.0 S | |
I-Trigger setting | Auto, 1-3 level | |
E-Trigger setting | Auto, 1-3 level | |
Trigger lock | Off, 0.3-1.5S | |
Flow of HFNC mode | N/A | 10-70L/min |
Max flov | 210L/min | 300L/min |
Max leak compensation | 90L/min | 120L/min |
Method of pressure measure | The pressure testing tube is on mask side | |
Alarms | Apnea | Disconnection | Low minute volumel Low tidal volume | Power off | Over high pressure | Oxygen unavailable | Excessive oxygen pressure supply | Low oxygen pressure supply | Pressure tube off | Turbine dysfunction|Oxygen sensor failure | Air flow sensor failure | Low pressure | Low battery | Battery depleted | |
Apnea alarm range setting | 0s, 10S, 20S, 30S | |
Disconnection alarm range setting | 0S, 15S, 60S | |
Real-time monitoring data | Preset oxygen concentration | Oxygen source pressure | Pressure | Ventilation per min Respiratory rate | Current leakage | Current volume | Trigger method |
|
Other setting | Screen lock | Display brightness | Flow|Pressure | Waveform | Screen lock |Display brightness | Flow|Pressure | Waveform | Event summary |
Backup battery | 8 hours |
Humidifier parameters
ST-30H | ST-30K | |
Heating range | 40-70. | |
Adjustment | 1-9 level |